Finish
Professional Series PR 2-in-1
Contractor Series CS – 75W
#304 Stainless Steel
#304 Stainless Steel
Item Number with Wattage
15PRD600SS - 600W
15CS75SS - 75W
Input Voltage
120V
120V
Output Multi-Taps
12/13/14/15 Volts.
2 separate sets of multi-tap output with angled terminal blocks for easy wire input.
12/15 Volts
Core and Coil
High-efficiency toroid core and coil configuration
High-efficiency fully encapsulated toroidal
Door Style
Easy magnetic flip-and-stay-open door
Removable front plate with two locking screws
Easy-Connect Terminal Lug Capacity
Up to 8, #10-gauge wires or
up to 10, #12-gauge wires per tap
Up to 14, #16-gauge wires per tap
Secondary Side Protection
Magnetic breaker
Magnetic breaker
Timer/Photocell
Compatible with plug-in timers and photocells. Two timer outlets for independent zone control of 2 independent lighting zones.
Integrated mechanical timer; plug-in photocell compatible
Cord
6' of usable #16-3 SJTW cord
6' of usable #18-3 SJTW cord
Conduit Knockouts
4 pre-punched field knockouts sized for .5" or .75" conduit (trade sizes) and one large center 1.75" inlet
2 pre-punched field knockouts sized for .5" or .75" conduit (trade sizes)
Notes
Includes mounting hardware. Comprised of 2-300W independently controlled transformers.
Includes mounting hardware. Dedicated wire loop for testing primary voltage. Department of Energy certified. Safety listings: cUL 1838, CSA 22.2.
Accessories
15556WH Digital Timer 15557BK Mechanical Timer 15565BK Standard Photocell 15534BK 10' Remote Photocell 15511BK Synchronizer
15556WH Digital Timer 15557BK Mechanical Timer 15565BK Standard Photocell 15534BK 10' Remote Photocell 15511BK Synchronizer
Dimensions
21.25" L x 6.75" W x 5.75" D
8.23" L x 3.67" W x 4.59" D