Page 196 - KHovanian Homes - Pathway to Homeownership
P. 196

                Section 13 | Standard of Performance   DEFICIENCIES & DEFINED STRUCTURAL ELEMENT FAILURE (10 YEAR STRUCTURAL WARRANTY) DEFICIENCY (IES) means defects in materials or workmanship used in constructing the HOME. The defects must fail to conform with the standards and tolerances described in the STANDARD OF PERFORMANCE section of this BUILDER’S LIMITED WARRANTY. OUR failure to complete the HOME or any portion of the HOME does not constitute a DEFICIENCY. DEFINED STRUCTURAL ELEMENT FAILURE means that one or more of the structural elements identified below contains a flaw of such a magnitude that the warranty tolerance is exceeded. The only structural elements WE cover and their respective tolerances are as follows:    Defined Structural Element Arches / Masonry Floor Systems / Structural Concrete Floor Systems / Joists Floor Systems / Trusses Foundation / Concrete Beams Foundation / Wood Beams: Built-up, Laminated or Solid Foundation / Steel Beam Foundation / Footings Foundation / Concrete Walls Foundation / Masonry Walls Foundation / Concrete Columns Foundation / Masonry Columns Foundation / Steel Columns Foundation / Wood Columns Lintels & Headers / Concrete, Masonry, Steel or Wood Roof Framing / Ridge Beam Roof Framing / Rafters – Common, Jack or Valley/HIP Roof Framing / Ceiling Joists Roof Framing / Trusses Structural Beams & Girders / Steel Structural Beams & Girders / Wood – Solid, Built-up or Laminated Structural Columns / Concrete 170 | Edition July 2019 Warranty Tolerance Crack of 1/4" in width in arch, or settlement in span of arch of 1/2" Crack of 3/16" in width and 3/16" vertical displacement DEFLECTION no greater than design spec' DEFLECTION no greater than design spec Crack of 1/8" in width, or DEFLECTION of 1/4" in 30" DEFLECTION of 3/4" in 8' DEFLECTION no greater than design spec Crack of 1/4" in width Crack of 1/4" in width and 1/4" vertical displacement Crack of 1/4" in width Bow of 1" in 8', or out-of-plumb 1" in 8' Out-of-plumb 1" in 8' measured from base of column Out-of-plumb 1" in 8' measured vertically Bow of 3/4" in 8', or out-of-plumb 3/4" in 8" DEFLECTION no greater than design spec DEFLECTION of 1" in 8' DEFLECTION or bow of 1" in 8' DEFLECTION no greater than design spec DEFLECTION no greater than design spec DEFLECTION no greater than design spec DEFLECTION no greater than design spec Bow of 1" in 8', or out-of-plumb 1" in 8'                                               


































































































   194   195   196   197   198